Specifications
Burette
Volumes Available 2.5/5/10/25 mL, ISO8655-3
Technical Attributes
Accessories Supported peripherals: printer, PC software, balance, sample changer, keyboard, mouse, barcode reader, sampling pump, propeller stirrer
Application 5
Automatic Reagent Addition(s) Integrated peristaltic pumps for reagent addition
Beaker Volumes Accepted System specific beakers: Polypropylene, 50 mL & 150 mL with clips
Generic beakers supported: Up to 250 mL low form glass
Burette 1
Burette Motor Resolution 20,000 steps with electronic µstepping technology (128 µsteps/step)
Calibration Titrant & electrode (up to 5 buffers in Auto Mode, fixed & user defined)
Calibration Curves Display Direct & derivative titration curves, electrode calibration curve
Calibration Intervals/Alerts/Reminder Yes, user defined period
Certifications Safety IEC/EN 61010-1; EMC IEC/EN 61326-1
Data Export On USB flash drive, CSV format, Excel compatible
Data Memory Last 100 samples, QC & blank analyses, last 10 calibrations
Data Storage Date, Time, Operator IDs, Sample IDs
Display Type 5,7"; Graphic color; VGA
Electrode IntelliCAL ("Plug & Play" digital), analog, photocolorimetric; 2 Inputs available
Embedded Procedures Tubing bubble purging, reagent priming, burette and pump replacement
Installation Category Category II
Languages English, German, French, Italian, Spanish
Maintenance Scheduler Yes, user defined
Material Enclosures PP Latene, silicone, hardened glass, POM, stainless steel. Splashproof design.
Measurement Method Potentiometric (zero & imposed current), amperometric, colorimetric
Measurement Modes End Point, Inflection Point - sample, blank, sample with blank, QC sample, QC sample with blank
Measurements mV/pH, Conductivity, Temperature (°C or °F)
Model AT1102
Operating Conditions 15 - 35 °C (59 - 95 °F), 20 - 80% RH, non-condensing
Operating Humidity 20 - 80% (non-condensing)
Operating Interface Soft keypad (Silicone)
Operating Temperature Range 15 - 35 °C (59 - 95 °F)
Outputs Electrode ports (x2), USB (x2), Serial (x1), Ethernet (x1)
Parameter mV/pH, Conductivity, Temperature
Password Protection Yes, user defined
Pollution Degree 2
Power Requirements (Hz) 50/60 Hz
Power Requirements (Voltage) 100/240 VAC
Pump flow rate 100 mL/min
Pumps 0
Required Application Package/s AP0001.AT1102 pH & Alkalinity in Water
AP0006.AT1102 Volatile Acids & Alkalinity (Biogas)
AP0008.AT1102 pH, Total Acidity (Milk, Tomato Sauce, & Fruit Juice)
AP0015.AT1102 TAN
AP0016.AT1102 TBN
Resolution mV/pH: ±0.1 mV / ±0.001 pH|Conductivity: ±0.5% of reading|Temperature: ±0.3 °C (32.54 °F)
Sample Stand Integrated, magnetic stirring, beakers up to 250 mL
Storage Conditions -5 - 40 °C (23 - 104 °F)
Supported Peripherals Printer, PC software, balance, sample changer, keyboard, mouse, barcode reader, sampling pump, propeller stirrer
Titration Modes Sample, blank, sample with blank, QC sample, QC sample with blank
Titration Types Potentiometric (zero & imposed current), amperometric, colorimetric
Warranty 12 months
Weight 4 kg (8.82 lbs)
What's included? Hach AT1102 Instrument, Tube Holder, Sensor Storage Tubes, Power Supply, Power Cord, Manual
Sold Separately: Don't forget to order your Application Pack and Reagents and consider purchasing an AS1000 Sample Changer